Engineering Specimen ID: ASA-AF-8820 Single-Variable Method

Fiberlogy ASA-AF Engineering Fit Test

Evaluating mechanical bore clearance and sliding friction tolerances on Fiberlogy ASA-AF printed engineering components using isolated XY hole compensation in PrusaSlicer 2.9.6.

Logged Date2026-08-14
Slicer ConfigPrusaSlicer 2.9.6
EvaluationTolerance Validated (±0.03 mm)
Core Test Metric Validated
+0.08 mm Optimal XY Hole Offset
Download PDF Ledger
Fiberlogy ASA-AF Engineering Fit Test
Visual assessment under 5000K daylight fixture Specimen ASA-AF-8820

1. The Physical Question & Hypothesis

Hypothesis: Applying a +0.08 mm XY Hole Compensation in PrusaSlicer 2.9.6 eliminates internal diameter shrinkage in Fiberlogy ASA-AF without altering external wall dimensions or causing layer delamination.

Engineering components printed from carbon-fiber filled ASA material naturally suffer from anisotropic radial shrinkage during the cooling cycle. In nominal CAD geometry, a 12.00 mm diameter bore typically closes down to 11.84 mm due to the perimeter bead tension. Rather than altering CAD sketches or risking global dimensional drift via scale factors, this trial directly evaluates whether dedicated slicer-level compensation achieves smooth mechanical pin sliding.

2. Isolated Variable & Controlled Matrix

To adhere to the principle of isolating a single parameter, all environmental factors, chamber heating, print velocities, and extrusion multipliers remained unchanged between the reference baseline and the test specimen.

Parameter Baseline Setting Trial Value Control Status
Hotend / Heated Bed Temp 260°C / 105°C 260°C / 105°C Fixed
XY Hole Compensation 0.00 mm +0.08 mm Tested
Perimeter Print Speed 45 mm/s 45 mm/s Fixed

3. Observable Result & Measurement

Inspection using calibrated cylindrical pin gauges and a digital micrometer verified the physical fit characteristics across the full insertion depth of the specimen:

  • A precision ground 12.00 mm steel dowel pin inserted smoothly by hand with uniform tactile resistance and zero perceptible radial play.
  • Four-point orthogonal bore caliper measurements averaged exactly 12.02 mm (±0.015 mm tolerance band), fully resolving the baseline 0.16 mm constriction.
  • Outer boundary envelope dimensions remained strictly within ±0.02 mm of target CAD specifications, proving that outer geometry was not compromised.

4. Next Iteration Decision

The +0.08 mm XY hole compensation parameter is adopted as the standard baseline profile for all subsequent Fiberlogy ASA-AF functional assemblies. No further slicing trials are necessary for standard dowel pins. Next iteration will proceed to dynamic torque load verification on the mated joint.

Trial Workbook Logs

Print Speed Profile 45 mm/s Perimeters / 120 mm/s Infill
Hotend Temperature 260°C Hotend / 105°C Heated Bed
Layer Height / Nozzle 0.20 mm Layer / 0.40 mm Hardened Steel
Cooling Fan Ratio 15% Max (Active Enclosure @ 48°C)

Test Rig Setup

Hardware: Enclosed CoreXY Motion Rig with hardened steel toolhead and PEI textured build plate.

Measurement Calipers: Mitutoyo 500-196-30 Digital Caliper (Calibrated ±0.02 mm).

Standard Operating Procedure Recommendation

In PrusaSlicer 2.9.6 under Print Settings > Advanced > Slicing, set XY Hole Compensation to +0.08 mm for all load-bearing Fiberlogy ASA-AF housings requiring precision slip tolerances.

Specimen Observation Logs

Peer verification and engineering trial feedback
0 Recorded Logs

No observation logs recorded for this specimen yet. Be the first to submit verification data below.

Append Engineering Observation

Observations are permanently logged into the worksheet.